Helmut Fischer

DUALSCOPE FMP40

Part no. 605-024

Description
Due to automatic substrate material recognition and the integration of both measurement methods, these universal instruments are capable of measuring coatings on steel and iron (F) and on non-ferromagnetic metals (NF). Duplex coatings (lacquer/zinc) on steel can be measured simultaneously with the values of the lacquer and zinc coatings displayed individually. The portable  FMP40 represents precise measurement technology and are ideal for samples and control measurement. These user-friendly and sturdy instrument can be adapted to all requirements of coating thickness measurement using exchangeable measuring probes. The most significant statistical values are dis-played and can be stored together with the calibration in the instrument, ensuring quick and reliable operation.

Specifications


Additional features to DUALSCOPE FMP40
Instrument features
  • External key-triggered measurement acquisition, e.g. in hollow cylinders with small diameters
  • Audible and visual warning when tolerance limits are exceeded
  • Option Bluetooth or COM additional available to the default USB interface

Measurement application memory
  • Application memory for up to 100 measuring applications incl. calibration (adjustment settings)
  • Memory for up to 20,000 readings
  • Allocation of readings into up to 4,000 blocks
  • Date and time stamp for blocks
  • Application linking mode: Common normalization/calibration of measuring applications
  • Validation of the corrective calibration by test measurements on standards

Measurement strategies and evaluation
  • Stored specifications for measurements according to IMO PSPC, SSPC-PA2, QUALANOD and QUALICOAT
  • Capability to enable matrix measurement mode for correlated multi-point measurements
  • Averaging of measurement data: Only the mean value of several readings will be stored
  • Measurement acquisition through area measurement: Single readings are captured until probe lift-off and averaged
  • Outlier rejection settings for automatic elimination of erroneous measurements
  • Free-running display with additional presentation of the reading as an analog bar between the tolerance limits
  • Statistics display of the most significant values in the block and final results. Output of variance-analytical values
  • Graphical measurement display as a histogram
  • Capability of entering process tolerance limits and computation of the associated process capability indices cp and cpk

Scope of delivery
  • Carrying strap
  • 4 batteries
  • Printed guidelines
  • USB inter-face cable
  • Support CD with USB drivers
  • Operator‘s manual
  • Software program FISCHER DataCenter to evaluate, record and archive measurement data in a com-fortable way, software program PC-Datex to transfer measurement data into Excel sheets